Innovative Technology & Best-in-Class

Efficiency

The TLE Series UPS brings the latest power conversion technology to the marketplace, using a three-level inverter design and a multi-mode architecture that makes real time decisions between premium protection mode and premium efficiency mode. The TLE Series UPS was developed using GE's Design for Six Sigma (DFSS) methodology to ensure that the product meets customer requirements for reliability and quality.

GE Technology at Its Best

Highly reliable and efficient tri-level conversion Automatic or manual multi-mode generation

 

"Best of Both Worlds" Operating Efficiency

Up to 99% premium efficiency mode (filtered eBoost) Up to 97% premium protection mode (double conversion)

 

Electrical Environment Optimization

Unity (1.0) Output Power Factor High (0.99) Input Power Factor Less than 5% Input Current Harmonic Distortion

 

Physical Environment Optimization

Small footprint Front access only design for maintenance "Cable saver" design to allow +/- 25% differential of cable lengths between UPS modules and the output parallel 
t: (902) 468-6968 tf: (888) 472-3919
Universal Power Solutions Inc.
Universal Power Solutions Inc.
Download Brochure Download Brochure
GE UPS

TLE Series UPS

225-1500kW

60Hz/ UL listed

Innovative Technology

& Best-in-Class

Efficiency

The TLE Series UPS brings the latest power conversion technology to the marketplace, using a three-level inverter design and a multi- mode architecture that makes real time decisions between premium protection mode and premium efficiency mode. The TLE Series UPS was developed using GE's Design for Six Sigma (DFSS) methodology to ensure that the product meets customer requirements for reliability and quality.

GE Technology at Its Best

Highly reliable and efficient tri-level conversion Automatic or manual multi-mode generation

 

"Best of Both Worlds" Operating

Efficiency

Up to 99% premium efficiency mode (filtered eBoost) Up to 97% premium protection mode (double conversion)

 

Electrical Environment Optimization

Unity (1.0) Output Power Factor High (0.99) Input Power Factor Less than 5% Input Current Harmonic Distortion

 

Physical Environment Optimization

Small footprint Front access only design for maintenance "Cable saver" design to allow +/- 25% differential of cable lengths between UPS modules and the output parallel 