Centric 480

Centric 208

Info & Details

Centric 208V UPSs offer uninterruptible power supply that can accommodate on your needs. Comprised of two different UPSs systems, Gamatronic’s Centric 208V family of products includes: • Centric 208V 60kVA/54kW with internal batteries • Centric 208V 160kVA/144kW with external batteries

Features

Internal batteries and allows to save space for 60kVA/54kW units Provides back up time Uses 20Ah batteries 19” cabinet 42U rack

Benefits

High power density Small footprint All major components are hot swappable Built in maintenance bypass Easy to maintain Smart and user-friendly system controller

General

Online double-conversion architecture. User-friendly interface. AC-AC efficiency up to 94%. Small footprint. Transformerless design. Compatible with 3-wire and 4-wire infrastructure
t: (902) 468-6968 tf: (888) 472-3919
Universal Power Solutions Inc.
Universal Power Solutions Inc.
 Download Brochure
NEW  COMING FALL 2018
EMF as per ICNIRP Battery Location Quantity 0.99 3% @80% load Voltage Range Current Frequency (Hz) Power Walk In Power Factor THDI 40 - 70Hz Configurable 10 to 60 sec. Output ± 0.5,1, 2 ,3 , 4 Hz selectable up to 1Hz/sec < 2% for linear Load; <6 for non-linear load Freqency Tracking Range  Slew Rate Overload withstand THD UL 1778 4th edition; IEC62040-1-1 UPS General Load Crest Factor Ac-Ac efficiency ECO MODE Type 6:1 Up to 99% Number of batteries Batteries Ac-Ac efficiency (nominal) Dc-Ac efficiency (nominal) Up to 94% Up to 97% at full load ±1 % VLRA Ambient Temperature THD (%) internal with option for additional  external battery connection External 8 3 Continuous CENTRIC 208 SPECIFICATIONS 3x 208 Vac 4 wire + Gnd 95-135 with derating (Max 62A) 62 Amps per Module, No inrush current at Startup Operation Voltage Topology Input Centric Model 60kVA 160kVA Power 60kVA / 54kW 160kVA / 144kW Standards IEC62040-2; FCC part 15-B.  14°F to 104°F (operating), -4 to 140°F(storage) 95 % max non-condensing  1500 m without derating  Multi-Fan with speed control (forced)  Cooling system IP20 Enclosure Relative Humidity Altitude IE 62040-3 Voltage Regulation for Unbalance Load (%) Static Regulation Design Classification EMC Emission Safety Low magnetic field radiation +/-1 for 100% unbalance load 3 x  208 Modular, Double-Conversion, VFI Dynamic Response to 100% Load Step +/-2 up to 125% for 10 minutes Less than 2 % for linear nominal load Load Crest Factor (Max) Sinusoidal 32
Centric 480

Centric 208

Info & Details

Centric 208V UPSs offer uninterruptible power supply that can accommodate on your needs. Comprised of two different UPSs systems, Gamatronic’s Centric 208V family of products includes: • Centric 208V 60kVA/54kW with internal batteries • Centric 208V 160kVA/144kW with external batteries

Features

Internal batteries and allows to save space for 60kVA/54kW units Provides back up time Uses 20Ah batteries 19” cabinet 42U rack

Benefits

High power density Small footprint All major components are hot swappable Built in maintenance bypass Easy to maintain Smart and user-friendly system controller

General

Online double-conversion architecture. User-friendly interface. AC-AC efficiency up to 94%. Small footprint. Transformerless design. Compatible with 3-wire and 4-wire infrastructure
Universal Power Solutions Inc.
Download User Manual Download User Manual Download Brochure Download Brochure